Product Structure
·A flexible conductor composed of multiple strands of bare copper wire or tin-plated copper wire twisted together
The performance of bare copper wire shall comply with GB/T 3953-2009; the performance of tin-plated copper wire shall comply with GB/T 4910-2009; the conductor structure shall conform to GB/T 3956-2008 or customer requirements.
·Cross-linked polyolefin insulation; silicone rubber insulation
The performance of insulating materials shall comply with GB/T 2951-2008; the outer diameter of finished wires and cables shall comply with GB/T 2951-2008; the electrical performance of finished wires and cables shall comply with GB/T 3048-2007.
Technical Data
·Temperature range: Cross-linked polyolefin insulation: -40~+125℃/150℃; Silicone rubber insulation: -60~+180℃
·Rated voltage: U0/U 600V/900V; 1000V/1500V
·Test voltage: 5000V
·Bending radius: When the cable diameter ≤ 10mm, not less than 4 times the outer diameter of the cable; When 10mm < cable diameter ≤ 20mm, not less than 6 times the outer diameter of the cable; When the cable diameter > 20mm, not less than 8 times the outer diameter of the cable
·Insulation resistance: ≧100MΩ/KM
·Radiation resistance: up to 20 x 10⁶ cJ/kg (up to 20 Mrad)
Product Features
· Excellent environmental friendliness, odorless and non-toxic, excellent antithrombogenicity and biological inertness; excellent electrical insulation properties; high temperature resistance, long-term operating temperature of 180°C, short-term temperature resistance up to 220°C; low temperature resistance, minimum operating temperature of -60°C; oil and chemical reagent resistance, silicone rubber has moderate oil and solvent resistance; high-temperature silicone rubber cables have stable electrical performance under high temperature environments, good aging resistance, and long service life; can be used in long-term humid environments with excellent electrical performance, water resistance, and mold resistance; silicone rubber is very soft, has good elasticity, excellent bending performance, and is easy to install.
· Optional - Corrosivity of combustion gases (halogen-free) complies with DIN VDE 0482 Part 267, DIN EN 50267-2-2, IEC 60754-2 (equivalent to DIN VDE 0472 Part 813); Non-flame propagation performance in fire complies with DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent to DIN VDE 0472 Part 804 Test Method B).
· Free of hazardous substances, compliant with ROHS standards.
Application Scope
· Connecting high-voltage batteries, electronic control units, and electric motors.
· Internal connecting wires for high-voltage appliances such as air conditioners and auxiliary heating.
· Internal connecting wires for battery PACK system BMS.
· Connecting wires between the charging port and the battery pack or charger.