Product Structure
-Multiple bare copper or tinned stranded soft conductor
For the performance of bare copper wire, refer to GB/T 3953-2009; for the performance of tinned copper wire, refer to GB/T4910-2009; for the conductor structure, refer to GB/T3956-2008 or customer requirements
-Cross-linked polyolefin insulation; silicone rubber insulation
For the performance of insulating materials, refer to GB/T2951-2008; for the outer diameter of finished wires and cables, refer to GB/T2951-2008; for the electrical performance of finished wires and cables, refer to GB/T3048-2007
-Tinned copper braided shield (coverage >= 80%)
-Aluminum foil wrapping
-Cross-linked polyolefin sheath; silicone rubber sheath
For the performance of insulating materials, refer to GB/T2951-2008; for the outer diameter of finished wires and cables, refer to GB/T2951-2008; for the electrical performance of finished wires and cables, refer to GB/T3048-2007
Technical Data
· Temperature range: -40~+125℃/150℃; -60~+180℃
· Rated voltage: U0/U 600V/900V; 1000V/1500V
· Test voltage: 5000V
· Bending radius: When the cable diameter is less than or equal to 10mm, it shall be no less than 4 times the outer diameter of the cable; when the wire diameter is greater than 10mm and less than or equal to 20mm, it shall be no less than 6 times the outer diameter of the cable; when the cable diameter is greater than 20mm, it shall be no less than 8 times the outer diameter of the cable.
· Insulation resistance: ≧100MΩ/KM
· Radiation resistance: up to 20 x 106 cJ/kg (up to 20 Mrad)
Product Features
· Excellent environmental friendliness, odorless and non-toxic, excellent antithrombogenicity and biological inertness; excellent electrical insulation properties; high temperature resistance, long-term operating temperature of 180°C, short-term temperature resistance up to 220°C; low temperature resistance, minimum operating temperature of -60°C; oil and chemical reagent resistance, silicone rubber has moderate oil and solvent resistance; high-temperature silicone rubber cables have stable electrical performance under high temperature environments, good aging resistance, and long service life; can be used in long-term humid environments with excellent electrical performance, water resistance, and mold resistance; silicone rubber is very soft, has good elasticity, excellent bending performance, and is easy to install.
· Optional - Corrosivity of combustion gases (halogen-free) complies with DIN VDE 0482 Part 267, DIN EN 50267-2-2, IEC 60754-2 (equivalent to DIN VDE 0472 Part 813); Non-flame propagation performance in fire complies with DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent to DIN VDE 0472 Part 804 Test Method B).
· Free of hazardous substances, compliant with ROHS standards.
Application Scope
· Connecting high-voltage batteries, electronic control units, and electric motors;
·Internal connecting wires for high-voltage appliances such as air conditioners and auxiliary heating
· Internal connecting wires for battery PACK system BMS
· Between the charging port and the battery pack or charger."